Exist 3 phase/Delta/120º phase angle power supply will be distributed from our panel to the total load Neutral is available.We are the Leading Manufacturer and Supplier of Phase Loss Corrector with Phase Sequence Corrector in Chennai,Tamilnadu,India. Where one phase fails in three phase line,it converts to three phase with sequence corrector. "We are looking for inquiries from South India region including Andhra Pradesh, Karnataka, Kerala and Tamil Nadu and cities like Bangalore, Chennai and Hyderabad."
Can load three phase and single phase systems. Digital meter is available for voltage current frequency. Input, output phase indications are available. All comes in 16SWG/ wall / floor mountable powder coated in siemens grey colour. Maintaining and reaching the international standards and requirements. When two phases fails at main, it will cut off the whole load. When the original all 3ph lines are restored, after a delay of a minute, the original 3ph will be supplied to the load. The phase conversion takes few seconds. Invariably, the failure of R’ phase or Y’ phase or B’ phase will be sensed by the Phase Converter and the angles between the available Phase lines will be formed, to support the load, with Delta/120º angle of perfect power supply. If any one phase fails, it cut off the load and Converts into 3ph/ Delta /R, Y, B phase lines/120º angle perfect power supply will be distributed to the load. Exist 3 phase/Delta/120º phase angle power supply will be distributed from our panel to the total load. World advanced Microcontroller technology is used. We are the Leading Manufacturer and Supplier of Two Phase to Three Phase Converter in Chennai,Tamilnadu,India. In order to improve the wiring simplicity and reliability, the signal line using pressure wire rod terminal is recommended.To run the three phase machinery, motor,UPS, ACs and Lift with two phase current. The stripped shield layer should be wrapped with insulating tape to prevent introduce interference from shielded cable and other equipment. In the wiring must note that the cable stripping should be as short as possible (5-7mm). Analog control signal line should be used double stranded shielded wire, wire size 0.75mm2. For there is no built-in reactor, the VFD input and output power line will have a strong interference on the outside, so the metal conduit or metal hose must be extended to the VFD control terminal to ensure that the signal line thoroughly separate from the power line. Signal lines and power lines must be placed in different metal conduits or metal hose: If the PLC and the VFD signal line are not placed in metal conduit, it will be easily affected by the external interference and VFD. The maximum length of the control circuit between the signal and the VFD should not exceed 50m. Even in the control cabinet, the wiring specification should be maintained. Signal line and power line must be separated: When using analog signals for remote control of the VFD, in order to reduce interference, the signal line and strong circuit (main circuit and sequential circuit) should be separated, and the distance should be above 30cm. –20℃~ +60℃ no dust, no corrosive gas, no direct sunlight
≤1000m VFD will be derated if above 1000m –10℃~ +40℃ VFD will be derated if ambient temperature exceed 40℃ each rise 1℃, the derate will be 5% Limit running current automatically to avoid frequent over-current which will cause trip Optimize V/F curve automatically based on the load to realize power save runningĬan keep constant output voltage when power source voltage varies.
2 phase to 3 phase converter manual#
150% of rated current for 1 minute, 180% of rated current for 3 secondsĪutomatic torque boost, manual torque boost 0.1%~30.0%